Compressor unit 4GU0.5-0.62/1.5-211S

(compressor unit mini CNG filling station)

Designed for refueling cars with compressed natural gas (methane). Category and group of explosion-proof mixture – PAT1. The unit is produced in climatic version U1 in accordance with GOST 15150-69, but for ambient temperatures from minus 30 °C to plus 40 °C and can be operated under a canopy.

Name of parameters and sizes Unit Norm

measurements

Compressible gas natural gas according to GOST

5542-87 and GOST 27577-2000

Explosiveness of gas when it is contained in air by volume from 5 to 15%
Volumetric capacity, reduced to normal conditions at minimum initial gas pressure and at maximum initial gas pressure, not less than m3/cm3 /min) 0,0167+/-0,0008 (1,0+/-0,05)

0,0283+/- 0,0014 (1,7+/-0,085)

Gas pressure initial, minimum, redundant MPa (kgf/cm2) 0,05 (0,5)
Gas pressure initial, maximum redundant MPa (kgf/cm2) 0,196 (2,0)
Gas pressure final, nominal, excess MPa (kgf/cm2) 20,7 (211)
Outlet pressure, excess MPa (kgf/cm2) 19,6 (200)
Initial gas temperature K (°C) from 243(minus 30)

to 318 (45)

Final gas temperature K (°C) 333 (60)
Cooling of compressed gas Air
Gas dew point after drying °C minus 60
Power consumed by the compressor, no more kW 23
Rotation frequency Art-1(rpm) 24,17 (1450)
Compressor drive AIMM180M4U2.5

N=30 kW

IM1081

Electric motor

 explosion-proof

 n=1470 rpm, ‚ IЕхdIIВТ4

Fan drive AIMM90L2U2.5

N=3.0kW

IM1081

Electric motor

 explosion-proof

 n=2850 rpm, ‚ IЕхdIIВТ5

Station power supply voltage IN 220/380
Current frequency Hz 50
Permissible supply voltage fluctuations % +10

-5

Total power consumed by the installation at maximum productivity and final pressure, no more kW 25
Power supply for control systems, fire extinguishing, emergency lighting and signaling is carried out from the network DC voltage IN 24
Overall dimensions of the compressor unit, no more mm length 2720

width 1620

 height 1700

Unit weight included in delivery, not more kg 2200