Pump type
SE 1250-45-11
Pump type
SE 1250-45-11
The SE 1250-45-11 pump and the unit based on it are designed for pumping water in district heating networks. The water must not contain solid particles larger than 0.2 mm and with a concentration exceeding 5 mg/L.
The pumps are manufactured in the UHL climate version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially controlled climatic conditions according to GOST 15150-69.
- Certificate of Conformity Ukraine
- Overal dimensions
- Performance range
| Pump designation | FLOW RATE, m3/h | Pressure, m | ROTATION SPEED, rpm | ALLOWABLE NET POSITIVE SUCTION HEAD, m | Pump efficiency, % | Motor power, kW | Pump weight, kg | Unit weight, kg |
|---|---|---|---|---|---|---|---|---|
| SE 1250-45-11 | 1250 | 45 | 1500 | 7,5 | 82 | 200 | 2300 | 3810 |
APPLICATION OF THE SE 1250-45-11 DISTRICT PUMP
The SE 1250-45-11 district pump belongs to a special group of power pumps, characterized by temperature fluctuations of the supplied water over a wide range of flows, and is designed to pump water with a temperature of up to 180 °C in district heating networks.
TECHNICAL CHARACTERISTICS
Nominal Pump Parameters
| Parameter | Value |
|---|---|
| Flow, m³/h | 1250 |
| Head, m | 45 |
| Allowable Cavitation Margin, m* | 7.5 |
| Efficiency, % | 82 |
| Temperature, °C | 10–180 |
| Rotation Speed, rpm | 1500 |
*This parameter is important to consider when designing the external network (pipeline system and fittings) and selecting pump equipment.
Dimensions and Weight
| Parameter | Pump | Unit |
|---|---|---|
| Weight, kg | 2300 | 3810 |
| Dimensions (W×L×H), mm | 1800×1796×1235 | 1800×3160×1340 |
The SE 1250-45-11 district pump is driven by a squirrel-cage asynchronous electric motor with a power of 200 kW. The overall efficiency of this system is 78 %.
MAIN REQUIREMENTS FOR SE 1250-45-11 PUMP DESIGN
- High reliability and cost-effectiveness
- External tightness and absence of internal leaks at rotor and stator joints
- Long service life – mean time to overhaul not less than 31,500 hours (when all maintenance requirements are met)
- Dynamic stability across the entire operating range
- Stable, continuously decreasing head curve for reliable operation when pumps are connected in parallel
- Ease of assembly, disassembly, maintenance, and high serviceability under operating conditions
CONSTRUCTION FEATURES OF THE SE 1250-45-11 PUMP
- Horizontal design providing high vibration resistance, reduced shaft misalignment, and extended service life of components
- Spiral type with horizontal split along the pump axis, allowing easy maintenance, assembly, and operation. Inlet and discharge nozzles are located at the bottom for pump assembly/disassembly without disconnecting pipelines
- Single-stage with a double-suction impeller made of two halves
- Pump casing is a complex cast iron structure in two parts (pump cover and pump body), with semi-spiral inlet channels and double-spiral discharge, including chambers (thermal barriers) for cooling fluid supply and discharge to mechanical seals. Bottom section includes inlet/discharge nozzles, support feet, trough-like brackets for leakage collection, and bearing mounts. Support feet are close to the pump axis to minimize misalignment during heating. A longitudinal keyway fixes the casing to the foundation frame for directed thermal expansion
- Rotor is a separate assembly consisting of shaft, double-suction impeller in two halves, bushings, protective bushings, bearings, and half-coupling. Axial movement of the impeller is fixed with bushings and protective bushings with round nuts. Thermal gaps compensate for thermal expansion of rotor components
- Rotor is axially unloaded using the double-suction impeller
- Rotor bearings are sliding bearings. Drive-side bearing handles radial loads; the other bearing is a combination of sliding and double-row angular contact ball bearing for radial and residual axial loads. Lubrication is liquid, ring-type (sump) with oil rings. Cooling jackets are provided in the bearing housings
- Mechanical seals are of gland type with a seal ring. Cooling and prevention of air suction are provided by circulation chambers and supply holes for pressurized cooling fluid
- Torque is transmitted from motor to pump via flexible sleeve-finger coupling
MATERIAL EXECUTION OF THE SE 1250-45-11 PUMP BY CHT SLOVAKIA S.R.O.
High reliability, durability, and efficiency are ensured by high-quality materials. Pump casing and bearing housings are made of cast iron СЧ200 for strength and corrosion resistance. Shaft is made of heat-treated steel 40Х for high strength and wear resistance. Impeller and protective bushings are made of stainless steel 20Х13; sealing rings – stainless steel 30Х13, ensuring efficiency and long service life.
ADDITIONAL SUPPLY OPTIONS FOR SE 1250-45-11 PUMP
- Mechanical seal to reduce leakage and improve energy efficiency, easy to maintain
- Higher-grade materials and coatings for pump flow parts to increase erosion resistance
- Flexible plate coupling between motor and pump to improve vibration characteristics and reliability
- VDS monitoring system with vibration, speed, and temperature sensors for condition monitoring, early problem detection, and maintenance planning
PURCHASE OF SE 1250-45-11 PUMP FROM CHT SLOVAKIA S.R.O.
To order a specific unit or get consultation for selection, contact our sales department by phone on the website or submit a request via the feedback form. Products are delivered to all CIS countries (except RF and BY) and European countries.