Author: info@eu-sumnt.com
Pump type
Pump type
PE 720-185
Centrifugal feed pumps PE 720-185 are designed to supply water to stationary steam boilers, with absolute vapor pressure up to 6.2 MPa (63 kgf / cm²). Feed water should have pH 7-9,2, the temperature not more than 438K (165 °C) and should not contain solid particles.
Pumps are manufactured in a climatic category of a moderately cold climate – they are designed for macroclimatic regions with temperate and cold climates, placement category 4 – operation in rooms (volumes) with conditioned environment.
Pump type
SE 500-70-16
The SE 500-70-16-C pump and the unit based on it are designed for pumping water in district heating networks. The water must not contain solid particles larger than 0.2 mm or in concentrations exceeding 5 mg/L.
The pumps are manufactured in UHL climate version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially controlled climate conditions according to GOST 15150-69.
- Certificate of Conformity: Ukraine
- Overal dimensions
- Performance range
Pump type
SE 800-55-11
The SE 800-55-11-C pump and the unit based on it are designed for pumping water in heating networks. The water must not contain solid particles larger than 0.2 mm or with a concentration exceeding 5 mg/L.
The pumps are manufactured in the UHL climate version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially regulated climatic conditions according to GOST 15150-69.
- Certificate of Conformity: Ukraine
- Overal dimensions
- Performance range
Pump type
SE 800-100-11
The SE 800-100-11-C pump and the unit based on it are designed for pumping water in district heating networks. The water should not contain solid particles larger than 0.2 mm or exceed a concentration of 5 mg/l.
The pumps are manufactured in the UHL climatic version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in indoor spaces with artificially controlled climate conditions according to GOST 15150-69.
- Certificate of Conformity Ukraine
- Overal dimensions
- Performance range
Pump type
SE 1250-45-11
The SE 1250-45-11 pump and the unit based on it are designed for pumping water in district heating networks. The water must not contain solid particles larger than 0.2 mm and with a concentration exceeding 5 mg/L.
The pumps are manufactured in the UHL climate version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially controlled climatic conditions according to GOST 15150-69.
- Certificate of Conformity Ukraine
- Overal dimensions
- Performance range
Pump type
SE 1250-70-11
The SE 1250-70-11 pump and the unit based on it are designed for pumping water in heating networks. The water must not contain solid particles larger than 0.2 mm or with a concentration exceeding 5 mg/l.
The pumps are manufactured in the UHL climate version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially controlled climatic conditions according to GOST 15150-69.
- Certificate of Conformity Ukraine
- Overal dimensions
- Performance range
Pump type
SE 1250-140-11
The SE 1250-140-11-C pump and the unit based on it are designed for pumping water in heating networks. The water must not contain solid particles larger than 0.2 mm or in concentrations exceeding 5 mg/l.
The pumps are manufactured in UHL climatic version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially regulated climatic conditions according to GOST 15150-69.
-
- Overal dimensions
- Performance range
- Certificate of Conformity Ukraine
Pump type
SE 2500-180-8
The SE 2500-180-8 pump and the unit based on it are designed for pumping water in heating networks. The water must not contain solid particles larger than 0.2 mm and with a concentration higher than 5 mg/L.
CLIMATE VERSION
The pumps are manufactured in the UHL climate version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially controlled climate conditions according to GOST 15150-69.
- Overal dimensions
- Performance range
- CERTIFICATE OF CONFORMITY Ukraine
Pump type
SE 2500-60-11-1
The SE 2500-60-11-1 pump and the unit based on it are designed for pumping water in heating networks. The water must not contain solid particles larger than 0.2 mm or in concentrations greater than 5 mg/l.
The pumps are manufactured in the UHL climate version — intended for macroclimatic regions with moderate and cold climates, placement category 4 — operation in rooms (volumes) with artificially controlled climatic conditions according to GOST 15150-69.
-
- Overal dimensions
- Performance range
- Certificate of Conformity Ukraine